|
Twitter
|
Facebook
|
Google+
|
VKontakte
|
LinkedIn
|
Viadeo
|
English
|
Français
|
Español
|
العربية
|
 
International Journal of Innovation and Applied Studies
ISSN: 2028-9324     CODEN: IJIABO     OCLC Number: 828807274     ZDB-ID: 2703985-7
 
 
Saturday 27 April 2024

About IJIAS

News

Submission

Downloads

Archives

Custom Search

Contact

  • Contact us
  • Newsletter:

Connect with IJIAS

  Now IJIAS is indexed in EBSCO, ResearchGate, ProQuest, Chemical Abstracts Service, Index Copernicus, IET Inspec Direct, Ulrichs Web, Google Scholar, CAS Abstracts, J-Gate, UDL Library, CiteSeerX, WorldCat, Scirus, Research Bible and getCited, etc.  
 
 
 

Simulation of the performance of the Potable Water Supply (PWS) network in the localities of Bébouo-Sibouo, Zaliouhan and Krébléguhé in the Gadouan Sub-Prefecture (Central-Western Côte d’Ivoire) using Epanet


[ Simulation du fonctionnement du réseau d’Alimentation en Eau Potable (AEP) des localités de Bébouo-Sibouo, Zaliouhan et Krébléguhé dans la Sous-Préfecture de Gadouan (Centre-Ouest de la Côte d’Ivoire) à l’aide du logiciel Epanet ]

Volume 40, Issue 3, September 2023, Pages 778–791

 Simulation of the performance of the Potable Water Supply (PWS) network in the localities of Bébouo-Sibouo, Zaliouhan and Krébléguhé in the Gadouan Sub-Prefecture (Central-Western Côte d’Ivoire) using Epanet

Arthur Brice Konan-Waidhet1, Affoué Berthe Yao2, OUEDE Gla Blaise3, Tanoh Jean-Jacques Koua4, and Dibi Brou5

1 Laboratoire des Sciences et Technologies de l’Environnement, UFR Environnement, Université Jean Lorougnon Guedé, Daloa, Côte d’Ivoire
2 UFR Environnement, Laboratoire des Sciences et Technologies de l’Environnement, Université Jean Lorougnon Guédé, Daloa, Côte d’Ivoire
3 University Jean Lorougnon Guédé, BP 150 Daloa, Côte d’Ivoire
4 Laboratory for Remote Sensing and Spatial Analysis Applied to Hydrogeology, Félix Houphouet-Boigny University of Cocody-Abidjan, Ivory Coast
5 Departement des Sciences de la Terre, Université Jean Lorougnon Guedé, Daloa, Côte d'Ivoire

Original language: French

Copyright © 2023 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract


The drinking water needs of the populations of the localities of Bébouo-sibouo, Zaliouhan and Krébleguhé are increasingly accentuated and constitute one of the major problems in this area of west-central Côte d’Ivoire. The aim of this work is to strengthen the drinking water supply system in order to meet the needs of the population. To solve this problem, the methodology was based on simulating the operation of existing and complementary networks using Epanet software. The results show that the population’s needs in 2019 are estimated at 400,032 m3/d and 685,406 m3/d in 2031. The pipes selected after sizing are all in PVC with nominal diameters of 10 bar, and comprise a PVC DN 200 mm for delivery, a PVC DN 90 mm for supply pipes (main pipe) and another PVC DN 53 mm for distribution. Simulation of the network shows that there is a malfunction in the existing system, which can be explained by the low or even zero pressures recorded only after 1 h of distribution throughout the existing network. Even if pressure results are good on the complementary network, low flow velocities are recorded on the whole network. As a result, further boreholes need to be drilled to boost production. This model will therefore be retained and used to support the implementation of this water supply project.

Author Keywords: Network sizing, water supply, Epanet, hydraulic simulation, Côte d’Ivoire.


Abstract: (french)


Les besoins en eau potable des populations des localités de Bébouo-sibouo, Zaliouhan et Krébleguhé sont de plus en plus accentués et constitue l’un des problèmes majeurs dans cette zone du Centre-ouest de la Côte d’Ivoire. Ce travail a pour objectif de renforcer le système d’approvisionnement en eau potable afin de répondre aux besoins des populations. Pour résoudre ce problème, la méthodologie a s’est appuyée sur la simulation du fonctionnement des réseaux existant et complémentaire à l’aide du logiciel Epanet. Les résultats révèlent que les besoins de la population en 2019 sont estimés à 400,032 m3/j et 685,406 m3/j en 2031. Aussi, les conduites retenues après dimensionnement sont toutes en PVC de diamètres nominales 10 bars et composées d’un PVC DN 200 mm pour le refoulement, un PVC DN 90 mm pour les conduites d’amenés (conduite principale) et d’un autre PVC DN 53 mm pour la distribution. La simulation du réseau montre qu’il y’a un dysfonctionnement du système existant qui s’explique par les pressions faibles, voire nulles enregistrées seulement après 1 h de distribution sur tout l’ensemble du réseau existant. Même si les résultats de pressions sont bons sur le réseau complémentaire, on enregistre sur l’ensemble du réseau des faibles vitesses d’écoulement. Ainsi, d’autres forages doivent être réalisés pour renforcer la production. Ce modèle sera donc retenu et servira de support pour la réalisation de ce projet d’AEP.

Author Keywords: Dimensionnement de réseau, AEP, Epanet, simulation hydraulique, Côte d’Ivoire.


How to Cite this Article


Arthur Brice Konan-Waidhet, Affoué Berthe Yao, OUEDE Gla Blaise, Tanoh Jean-Jacques Koua, and Dibi Brou, “Simulation of the performance of the Potable Water Supply (PWS) network in the localities of Bébouo-Sibouo, Zaliouhan and Krébléguhé in the Gadouan Sub-Prefecture (Central-Western Côte d’Ivoire) using Epanet,” International Journal of Innovation and Applied Studies, vol. 40, no. 3, pp. 778–791, September 2023.