|
Twitter
|
Facebook
|
Google+
|
VKontakte
|
LinkedIn
|
Viadeo
|
English
|
Français
|
Español
|
العربية
|
 
International Journal of Innovation and Applied Studies
ISSN: 2028-9324     CODEN: IJIABO     OCLC Number: 828807274     ZDB-ID: 2703985-7
 
 
Friday 17 May 2024

About IJIAS

News

Submission

Downloads

Archives

Custom Search

Contact

  • Contact us
  • Newsletter:

Connect with IJIAS

  Now IJIAS is indexed in EBSCO, ResearchGate, ProQuest, Chemical Abstracts Service, Index Copernicus, IET Inspec Direct, Ulrichs Web, Google Scholar, CAS Abstracts, J-Gate, UDL Library, CiteSeerX, WorldCat, Scirus, Research Bible and getCited, etc.  
 
 
 

Determination of physical and mechanical parameters of soil in the Niamey region (Niger) by using in situ and laboratory geotechnical tests


[ Détermination des paramètres physiques et mécaniques du sol de la région de Niamey (Niger) à l’aide des essais géotechniques in situ et au laboratoire ]

Volume 42, Issue 2, April 2024, Pages 326–337

 Determination of physical and mechanical parameters of soil in the Niamey region (Niger) by using in situ and laboratory geotechnical tests

Baraou Souley Idi1, Sani Abdoulwahid2, and Moussa Konaté3

1 Université d’Agadez, Faculté des Sciences et Techniques, Département de Géologie, P.O. Box 199, Agadez, Niger
2 Department of geology, University of Agadez, Niger
3 Université Abdou Moumouni de Niamey, Faculté des Sciences et Techniques, Laboratoire de Géologie: Eaux Souterraines et Géoressources, BP 10662, Niamey, Niger

Original language: French

Copyright © 2024 ISSR Journals. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract


The present study focuses in situ and laboratory determination of geotechnical parameters of soil samples from the Niamey region (Niger). The collected soil samples were analyzed at the geotechnical laboratory (GEO-LAB CONSULT). Petrographic analysis of samples from manual wells showed three stratas of varying thickness. From top to bottom, these are: medium to coarse yellowish-red sand (50 to 80 centimeters), lateritic gravel (20 to 40 centimeters) and ferruginous armour (40 to 60 centimeters). The obtained results from the penetrometer boreholes were used to determine the depth of the foundations, the thickness of the studied stratas and the ultimate stress of the soil for foundations dimensioning. At the Aeroport site, the depth of the lowest point is 1.5 meter, with an ultimate stress of 5.05 bars. The Satu site has a lowest depth point of one meter, with an ultimate stress of 7.47 bar. The Kalley Plateau site gave a lowest depth point of 1.5 meters with an ultimate stress of 2.20 bars, and the Saguia Béné site had a lowest depth point of 1.5 meter with an ultimate stress of 2.15 bars. Analysis of the water content of studied soils, combined with the penetrometric results, shows that water content influences soil strength.

Author Keywords: Geotechnical tests, soil, penetrometer drilling, manual well, physical and mechanical parameters, Niamey, Niger.


Abstract: (french)


La présente étude porte sur la détermination in situ et au laboratoire des paramètres géotechniques des échantillons de sol, prélevés dans la région de Niamey. Les échantillons de sol prélevés ont fait l’objet d’une description pétrographique et d’analyse au laboratoire d’expertise en géosciences de Niamey (GEO-LAB CONSULT). Les résultats obtenus par la description des différents lithofaciès ont montré trois niveaux d’épaisseur variables. Il s’agit de haut vers le bas de: sable moyen à grossier rouge-jaunâtre (50 à 80 centimètres, graveleux latéritique (20 à 40 centimètres) et la cuirasse ferrugineuse (40 à 60 centimètres). Les résultats obtenus par les sondages au pénétromètre ont permis de déterminer la profondeur des fondations, l’épaisseur des différents niveaux étudiés ainsi que la contrainte ultime du sol pour le dimensionnement des fondations. Ainsi, au niveau du site de l’aéroport, la profondeur du point le plus bas se situe à 1.5 mètres, avec une contrainte ultime de 5.05 bars. Le site de Satu a une profondeur du point le plus bas à 1m, avec une contrainte ultime de 7.47 bars. Le site de Kalley Plateau a donné une profondeur du point le plus bas à 1.5 mètres avec une contrainte ultime de 2.20 bars et le site de Saguia Béné a une profondeur du point le plus bas à 1.5 mètres avec une contrainte ultime de 2.15 bars. L’analyse des teneurs en eau des sols étudiés, combinée aux résultats pénétrométriques, montre que la teneur en eau influence la résistance du sol.

Author Keywords: Essais géotechniques, sol, sondage au pénétromètre, puits manuel, paramètres physique et mécanique, Niamey, Niger.


How to Cite this Article


Baraou Souley Idi, Sani Abdoulwahid, and Moussa Konaté, “Determination of physical and mechanical parameters of soil in the Niamey region (Niger) by using in situ and laboratory geotechnical tests,” International Journal of Innovation and Applied Studies, vol. 42, no. 2, pp. 326–337, April 2024.